User`s manual
2.2
Camera Rear Panel
The mating connector for the DC power input is manufactured by LEMO
as part number FGG.0B.302.CLAD42
TRIGGER
A coaxial SMA type connector that accepts CMOS TTL signal inputs with a
threshold of approximately 2.5 volts. The trigger pulse should have a duration of
at least 100 nanoseconds and be transmitted to the camera using a coaxial cable
terminated at the camera. The camera synchronizes to an external event using
this input. The operator can set the polarity of the trigger signal that the camera
will respond to. Timing waveforms are shown on page 4.5, and 4.6 of this manual.
STROBE
A coaxial SMA type connector that outputs a TTL compatible signal. The strobe
output pulse should be transmitted through a 50 ohm coaxial cable with a 50 ohm
terminating resistor at the receiving end. The leading edge of this output signal
can be used to fire a strobe light. The output signal polarity is user definable.
See timing Waveforms in chapter four of this manual.
TRIGGER
S
T
R
O
B
E
AIA VideoPower