Installation manual
630167_3_Manual_Service_ST900_US_R‐emotion
1.0 IsolatePowerandGasSupply:
BeforeanyserviceandmaintenanceworkisdoneontheST900,thegassupplymust
beisolatedorshutoff.Gascanbeisolatedbyeitherturningthegasoffatthe
cylinders,atthemeterorattheapplianceisolationvalve.Powercanbeisolatedby
removingthebatteriesfrom
thebatterypack.
2.0 RemovetheFascia:
Ensurethefasciahascooledbeforeattemptingtoremoveit.
TheST900fasciaattachestothefirebyfourhooks.Toremovethefascia,simplylift
itupwards5/8”‐3/4”,andpulltowardsyou.Careshouldalwaysbetakenwhen
handlingthefascia.
3.0 RemoveGlassAssembly:
Ensuretheglassassemblyhascooledcompletelybeforeattemptingtoremoveit.
Pullthefourhooksshownbelowtowardsyouandthenawayfromtheglassto
releasetheglassframeunderneaththehook.Lifttheglassassemblytowardsyou
to
clearthelocatingsupportsandplaceitflatuponsomenewspaperorasheetof
cardboardtoprotectyourfloorcoverings