14.0 Converting to Propane Gas:
Where a conversion to propane gas is needed, the following steps should be followed
14.1 First you need to remove the burner by
removing the screw holding it in place on the
left hand side of the firebox (Fig. 1).
Then remove the 1.9mm burner jet (Fig. 2)
and replace it with the 1.2mm jet supplied in
the kit.
Now remove the gas pipe fitting under the
pilot (Fig. 3) and remove the No.48 pilot Jet
(Fig. 4) and replace it with the No.46 pilot jet
supplied in the kit.
Replace pilot line.
Adjust the Primary Aeration Collar on the burner to the
Propane position as shown in the diagram below, then
place the burner into position and screw it in place.
The gas regulator needs to be converted from
the Natural Gas setting to the Propane setting.
The regulator is located on the left hand side of
the control tray, at the base of the fireplace. To
change the regulator between Natural Gas and
Propane, unscrew the top cap off the regulator
and pull the plunger from it. Re-insert the plunger
on the opposite side (as shown in the diagram to
the right) and screw the assembly back in the
stack