Installation manual

630288_0_Manual_Installation-Service_ST900_AUS NZ
9
5.1 Combustible Mantle Clearances:
The diagram to the right shows the minimum and
maximum allowable size for mantles or protruding
surfaces mounted above the ST900.
Note: Escea does not recommend placement of
items on the mantles shown in the diagram to the
right. This is because of the potential for items placed on
or above the mantle to be affected by the heat rising from
the appliance.
5.2 Non-Combustible Mantle Clearances:
If the entire installation (mantle, wall and cavity) is
constructed from non-combustible materials, the
clearances to mantles may be as shown in the shaded
area.
6.0 Corner Installations:
If a cavity is to be created in a corner,
the following table gives the minimum
sizes in millimetres.
Fascia Type
A
B
C
D
Ferro
380
910
835
1670
Velo
392
940
862
1724
7.0 Laying Gas Pipe:
Gas pipe should be sized as per the requirements of AS/NZS 5601. The pipe sizing must
be sufficient to deliver the following volume of gas to the fire with all other gas appliances in
the home running at the same time;
NG = 18Mj/hr
Propane/ULPG = 21Mj/hr