1.0 Isolate Power and Gas Supply:
Before any service and maintenance work is done on the fire, the gas supply must be
isolated or shut off. Gas can be isolated by either turning the gas off at the cylinders,
at the meter or at the appliance isolation valve. Power can be isolated by removing
the batteries from the battery pack.
2.0 Remove the Facia:
Ensure the facia has cooled before attempting to remove it.
The facia attaches to the fire by four hooks. To remove the facia, simply lift it
upwards 15-20mm, and pull towards you. Care should always be taken when
handling the facia.
3.0 Remove Glass Assembly:
Ensure the glass assembly has cooled completely before attempting to remove it.
Pull the four hooks shown below towards you and then away from the glass to
release the glass frame underneath the hook. Lift the glass assembly towards you to
clear the locating supports and place it flat upon some newspaper or a sheet of
cardboard to protect your floor coverings