Installation manual
630288_0_Manual_Installation-Service_ST900_AUS NZ
35
19.11 Initial configuration:
To enter the configuration menu, press the OFF button on the remote control for 40 seconds.
During this time the screen may go blank, this is normal. After 40 seconds, the configuration
menu appears.
It is possible to configure the appliance with the following options:
x Thermostat: This option enables or disables the auto thermostat mode. To enable it, select
Yes. To disable it select No.
x Gap Temp: This option refers to the tolerance between the desired temperature and the
current one. If the difference is greater than this gab temperature setting, the flame level
increases.
For example: the desired temperature is set at 20°C and the current temperature is 18°
x If the Gap Temp is 0•5°C: Flame level will go to maximum level because the difference
is 2°C.
x If the Gap Temp is 1°C: Flame level will go to medium level as difference of 2°C is two
times the gap setting. (The flame level increases two levels: Pilot → Low → Medium.)
x If the Gap Temp is 2°C: Flame level will go to minimum level as the difference of 2°C is
equal to the gap setting. (The flame level increases one level: Pilot → Low.)
x Programming: this option enables or disables the program mode. To enable it, select Yes.
To disable it, select No.
x Ember bed: this option enables or disables the ember bed output. To enable it, select Yes.
To disable it, select No.
x Safety temp: This temperature is the maximum permitted room temperature. If the remote
detects that the temperature is higher than the Safety temp, the appliance is switched off.
This temperature can never be set higher than 40°C (104°F). The possible range of values
is 25-40°C (77-104°F).
x Channel: There are three different channels available: A, B and C. A change of channel
should be done if communication is no good, and only after pairing has been done. Never
try to do channel change and a pairing at the same time. To change the channel just press
Select, choose one of the channels and then reset the control unit by disconnection the
power supply for a short period. Afterwards the connection between the remote and the
control unit will be re-established. This process can take 10 seconds.