Installation manual

630162_5EF5000InstallationGuideRemotion‐US
2.0 Power Supply:
This appliance requires 3 ‘D’ sized cell batteries for operation, which are located in a battery
pack inside the control tray behind the fascia, at the base of the fire. Alternatively, you can
use the External Power Supply, described in section 2.2 of this manual.
2.1 Replacing Batteries:
To replace the batteries, remove the fascia to gain access to the battery pack pictured
above. To remove the cap of the battery pack turn it anti-clockwise until it stops, then pull.
The batteries inside should slide out. Ensure you replace the batteries in the correct way,
dimple facing out.
Once the new batteries have been placed inside, replace the cap and turn it clockwise until it
stops, to seal it.
2.2 Alternate Power Source: (Optional)
+VE -VE
Alternative Power source
Connection Terminal
Battery Pack
If you wish to connect your outdoor fire to mains electricity instead of using 3x D sized
batteries, you may do so using the Alternative Power Source Connection Terminal, located
on the control tray above the battery pack, as shown above.
You will need to purchase a transformer capable of 5v DC output, with a minimum of 1.5
Amp capacity. Connect the transformer to the fire by putting the Positive wire into the Red
terminal of the control tray, then connect the Negative wire to the Black terminal.
THIS MUST ONLY BE DONE BY AN AUTHOURIZED ELECTRICIAN
Battery Pack