9.0 Fixing the fire into the cavity:
To fix the fire to the cavity, first drill 4 to 6 (3/16” diameter) holes in the outer flange (as
shaded grey in the picture below) in locations which will give you the most support from the
cavity framework behind, and evenly spaced around the flange. Using the supplied Stainless
Steel screws, fasten the fire to the cavity through these drilled holes.
Ensure that the fire is securely located and free from movement.
Suggested location of screws for mounting
10.0 Connecting the Gas Pipe:
When the fire unit has been pushed into position and secured the gas pipe can be
connected to the inlet side of the appliance regulator (BSP thread) at the front center of the
fire. The hose and pipe assembly should have been tested prior to this as per section 8.2
10.1 The regulator that is supplied in the fire MUST NOT BE REMOVED. Removal of the
regulator, or replacing it with one not intended for use with an Escea EF5000, will void the
limited appliance warranty.
10.2 The EF5000 must be isolated from the gas supply piping system during any pressure testing
of that system at test pressures in excess of ½ psi (14”WC).
The gas fireplace and its individual shutoff valve must be disconnected from the gas supply
piping during any pressure testing of that system at test pressures in excess of ½ psi (3.5
kPa – 14” w.c.).