Service manual
B
ACDEFGSERVICE
9
B3 Flue Conguration (For less than 4m length)
If your ue system is less than 4m long (as shown in the diagrams below), then a simple
exible ue is required. if you wish to install a longer ue run, up to 12m, see section B4.
4m MAX
X
Y
X + Y = 4m MAX
= 0.6m MIN
1.2m Co-axial Flue
Note: You must provide sucient access to the
powerue to enable it to be serviced in the future.
This means that the fan unit must have sucient
access to allow it to be replaced if necessary.
The ue must be securely xed and adequately supported by brackets fastened to the
building structure at suitable points to ensure the stability of the ue system.
Any joints within the ue system must be sealed adequately, with a sealing agent used
if necessary. The ue system for the DX1500 / DX1000 is zero rated, so no spaces are
required between the ue and any timber framing.
Horizontal Flue option
Minimum: 600mm ue length
Maximum: Total ue length 4m
Vertical Flue option
Minimum: 600mm ue length
Maximum: Total ue length 5.2m
For ue installation, see section D
ONLY USE ESCEA APPROVED FLUE COMPONENTS
Note: All sections of horizontal ue if exible must be sloped back toward the re at
a rate of no less than 20mm per metre, to allow any condensation to run back into
the appliance.
X
Y
X + Y Maximum = 4m
Y Maximum = 1.5m
Y Minimum = 0m
X Maximum = 4m
X Minimum = 0m
X + Y Minimum = 0.6m