Service manual
B
ACDE
F G SERVICE
34
Note: Improper positioning of any fuelbed media may create carbon build-up and will
alter the unit’s performance. Malfunctioning due to improper fuel media placement will
not be covered under warranty.
Reinstall the glass and retainer frame, being careful that the glass does not fall from the
frame. Tighten the bolts around the outside of the glass retainer until securely tted.
Do not over-tighten the glass retainer bolts. Just nip them up.
NOTE: If there is any residue left on the glass from the plastic wrap packaging
of the replace, it must be cleaned using any standard glass cleaner prior to
operation.
Note: If the glass gasket requires a replacement, call your nearest Escea agent who will
ensure the part is replaced with the correct type. In the event that the glass is broken by
impact, purchase the replacement from an authorised Escea agent only.
Conrm the appliance is working correctly by lighting it 2 or 3 times to ensure correct
operation & smooth ignition. Also conrm both ue and room duct fans are running cor-
rectly.
NOTE WHEN REPLACING THE GLASS:
When replacing the glass, note that the metal ange shown
to the right must be on top (not the bottom), or the glass will
not t correctly to the replace.
F3 Wall lining
Only after the above list is satised, can you commence with the nal wall linings.
The appliance and all corresponding ducting needs to be adequately covered (both sides
if double sided) to prevent plasterboard and building dust from entering the ducting
system during completion of the wall lining.
Wall lining cutout dimensions around the glass must be adhered to.
Please refer to section
B7 for wall nishing dimensions surrounding glass.
Ensure the air inlet gap surrounding the glass is maintained. The glass frames must still be
able to be removed after wall linings installed.