Service manual

B
ACD
E F G SERVICE
32
Home Automation Operation:
Relay closed
The replace will start in a medium setting until it receives a signal from the remote con-
trol unit (up to 4 minutes). Once the remote has communicated with the replace it will
turn on and begin operating the replace thermostatically. The remote will use whatever
temperature the user has previously set and cannot be altered by the home automation
system. The replace will continue to operate while the relay is closed.
Note: If the replace cannot communicate with the remote controller within 10 minutes
of the relay contact closure then the replace will shut down and return to standby. The
remote controller is required to be operating within range of the replace for its safe
operation.
Relay open
If the replace was operating with a closed relay then upon opening the relay contacts
the replace will shut down and return the remote controller to its standby mode when
it next updates (up to 4 minutes). While the relay is open the replace will be in standby
mode and available for manual operation by the user.
E12 Reinserting fuel bed and ceramic glass
Re-insert the 14 engine screws if removed.
Place the burners and Fuelbed Tray back into position.
If removed, place inspection panel back on.
At this stage you should relight the appliance to conrm correct ignition.
END OF SECTION E
By the end of this section, you should have:
The appliance installed in the cavity
The appliance xed to the cavity base and wall lining
The appliance plugged into a mains electricity supply
The appliance gas supply attached and pressure tested with all other gas appliances
running