Service manual
B
ACD
EFGSERVICE
31
E10 Auxillary On/O button
The auxillary on/o button is
used to turn the replace on
without the Remote Control,
and also used for “teaching”
the replace to listen for new
remote controls. For information
on teaching a new remote
control, see section S4 of the
service manual at the end of this
document.
The auxillary On/O button is
accessed by using an allen-key
or thin object to poke through in
the location shown to the right.
E11 Home Automation Setup
Escea D-Series replaces have a simple interface for connection to a home automation
system. Simply put this allows the replace to be woken up and started and then shut
down. The “Close to wake” connection shown is essentially taking one of the 3.3 volt DC
pins on the replace micro controller and pulling it down to ground. In order to isolate
the replace from the automaton system a relay needs to be used as shown. This allows
you to use any nominal voltage to drive the relay while keeping the replaces 3.3V supply
isolated.
μ
Terminal block
Connector
on fireplace
Fireplace
Connector and terminal
block supplied by Escea
+3.3VDC
From Automation system
Required relay
Note: you will need to match the relay coil voltage with the voltage from your automaton
system.
The Home Automation connection can
be found in your replace accessory
pack and is shown to the right.
This connects to the replace via the
removable access panel in the bottom
right of the replace, as shown in
section C2.