E8 Checking the Gas Operating Pressure
Note: Access to the valve and control system
can be through either of the 2 hatch panels
shown shaded black in the diagram to the
right.
Turn on the gas. Turn the power on.
Check the inlet pressure upstream of the
appliance using the test point that you
installed earlier.
Note: The regulator that is supplied with
the re MUST NOT BE REMOVED. Removal
of the regulator, or replacing it with one not
intended for use with an Escea re, will void
the limited appliance warranty and may be
dangerous.
The gas valve is shown right with Manometer test points at A and C, and an adjustment
point at B.
Gas Pressure Table - DX1000 Gas Type
Propane (AUS)
or ULPG (NZ)
Natural Gas
Minimum Inlet Pressure - Pre-Regulator 2.75 kPa 1.13 kPa
Maximum Inlet Pressure - Pre-Regulator 5.0 kPa 5.0 kPa
Operating Pressure when on high - (Point A) 2.32 kPa ±5% 0.82 kPa ±5%
Operating Pressure when on low - (Point A) 0.72 kPa ±5%
0.28 kPa ±5%
Max operating pressure - at burner jet 2.30 kPa 0.76 kPa
Operating pressure - Post-Regulator (Point C) 2.30 kPa 1.00 kPa
Gas Pressure Table - DX1500 Gas Type
Propane (AUS)
or ULPG (NZ)
Natural Gas
Minimum Inlet Pressure - Pre-Regulator 2.75 kPa 1.13 kPa
Maximum Inlet Pressure - Pre-Regulator 5.0 kPa 5.0 kPa
Operating Pressure when on high - (Point A) 1.96 kPa ±5% 0.76 kPa ±5%
Operating Pressure when on low - (Point A) 0.96 kPa ±5% 0.28 kPa ±5%
Max operating pressure - at burner jet 1.94 kPa 0.75 kPa
Operating pressure - Post-Regulator (Point C) 2.30 kPa 1.0 kPa