Step 5: Remove the regulator screw cap and screw out the nylon adjuster screw to
remove the existing spring. Replace the spring with the purple spring supplied in the
conversion kit and reassemble the regulator.
Step 6: Cover the existing gas type label with the new gas type label supplied in kitset.
Ensure serial number and date of manufacture are still visible. Write your name, company
(if appropriate) and date of conversion on new label with permanent marker.
Step 7: Place engine back into rebox. Take care not to pinch any wires. Don’t replace
the screws at this stage.
Step 8: The burner tubes on both burners have convertible collars. Ensure the collars on
both are set to the correct orientation. Place one burner only into position.
ULPG/Propane NG
11mm hole exposed 3.5mm hole exposed
Step 9: Adjusting the electronic controller for gas type
Ensuring the gas is still OFF, Turn the power ON.
On the remote control, insert the new AA size batteries. You
should now see the time on the display showing 0:00
Press the MINUS (4), PLUS (8) and FAN BOOST (7) buttons simulta-
neously (as shown right) until the characters “03” light up on the
display. Release the buttons and the remote will count down and
display “GO”. The screen will then display all characters. This will
put the remote into test mode and the two big temperature digits
should begin counting from 0 to 99 repeatedly.
Now hold down the Timer Select button and Activate Timer button simultaneously,
the remote display will show the current conguration of either “nG” for Natural or “LP
for ULPG/Propane. To change this conguration, hold down the same 2 buttons Timer
Select and Activate Timer simultaneously for 5 seconds. This will now have toggled
between gas types.
Once you are have chosen the correct gas mode, simply press the
power button
once to exit this diagnostics mode.