E7 Gas Type Conversion
THIS APPLIANCE IS CONFIGURED TO OPERATE ON NG
If gas type conversion is not required then jump to checking operating pressure
Note: Access to the valve and control system can be through either of the 2 hatch panels
shown shaded black in the diagram of section E8.
Your gas re has been supplied with the necessary parts for gas conversion. Follow the
steps on the following page to change from NG to ULPG/Propane or vice versa.
WARNING: The regulator that is supplied with the re MUST NOT BE REMOVED.
Removal of the regulator, or replacing it with one not intended for use with this Escea re,
will void the limited appliance warranty.
Turn o power and gas rst
Step 1: Ensure power and gas is o. Remove the fascia, glass and fuelbed as per
section E6
Step 2: Lift out the two burners and the surrounding perforated grill as per section E7.
Step 3: Remove the screws in the bottom and the inner side of the rebox as per shown.
Remove engine’ by lifting up and to the left. This is still connected internally to the gas
hose and power cables. Place engine just to the left within rebox as shown.
Step 4: Change the two main burner jets with the jets supplied in kitset.
DX1500 DX1000
NG (Both jets) Ø2.3mm Ø1.95mm
Propane / ULPG (Both jets) Ø1.3mm Ø1.10mm