Service manual
B
ACD
EFGSERVICE
25
E2 Installing the Appliance
Insert the gas re into the cavity and bolt down in correct
position using the brackets on each end of the appliance.
It is a requirement that this appliance be securely fastened
at the base.
On the right hand side of the appliance:
Connect the powerue electrical cable.
Connect the Duct fan electrical cable
Plug the appliance Mains power electrical cord into the
230/240volt outlet in the cavity.
E3 Connecting the Flue
Access the top of the appliance and
connect both the inlet ue (Ø75mm)
and the exhaust ue (Ø100mm) to
their respective spigots. Tighten the
hose clamps onto the spigots. En-
sure the ue connection is air tight.
Sealant is not required.
WARNING: The ue connection MUST be secured with the clips provided and
tape MUST NOT BE USED. If any of the ue pipe is damaged and integrity
compromised then it should not be repaired with tape, it should be replaced.
Connecting the Ducting
Attach the ducting to the top of the appliance at the 250 diameter spigot and secure us-
ing a clamp or appropriate ducting tape to ensure an airtight joint.
E4 Connecting the Network Cable
A network cable has been attached to the appliance. This must be left accessible even if
not being used, to make future servicing or upgrades easier. To access the network cable,
open the access hatch on the base of the rebox (underneath the burners) and feed the
cable through the holes in the outer chassis where the power and gas lines are.