Service manual

B
A C D E F G SERVICE
12
The Plasterboard is to protrude beyond framework as shown in the following diagram.
362
SideFront
362
192
DX1000:
MIN
1062
DX1500:
MIN
1562
Note: The wall lining directly above the appliance will get warm and hence may discolour
paint nishes that are susceptible to temperature damage or distort vinyl wall coverings.
For durability of nishes and surfaces you should contact the relevant manufacturer for
their specication and avoid materials with temperature ratings less than 80deg C.
B9 Fascia
If using a (velo) fascia, the cutout required in the nished plaster board dimensions are:
410
DX1000: MIN
1100
DX1500: MIN
1600
10
FA S C I A
Note that 10mm (or less) wall lining must be used when installing a DX-series replace with a
fascia, as this is the distance the fascia sits o the front face of the re as shown.
B10 Mantle Clearance
Please refer to the diagram. Mantles or protruding ledges above
the heater must not be installed lower than the dimension shown.
Note: dimension from base of appliance.
B11 Television Clearances
The following are the recommended minimum clearances for the
location of any electrical equipment (such as a Plasma TV, LCD TV
or home theatre system) above an Escea DX Series gas re.
Note: The above television clearance recommendations are to be
treated as a suggestion of a suitable installation only. It is the re-
sponsibility of the end user to check the installation instructions of
their electrical appliances to ensure that the location in relation to
the gas re is suitable. Escea in no way guarantees or takes respon-
sibility that the above installation suggestion will be suitable for all
electrical or home entertainment appliances.
Note: Dimension from base of appliance.
800
MIN
800
MIN
WALL OPENING
(WITH FASCIA)
WALL OPENING
(WITHOUT FASCIA)