Service manual
B
A C D E F G SERVICE
12
The Plasterboard is to protrude beyond framework as shown in the following diagram.
362
SideFront
362
192
DX1000:
MIN
1062
DX1500:
MIN
1562
Note: The wall lining directly above the appliance will get warm and hence may discolour
paint nishes that are susceptible to temperature damage or distort vinyl wall coverings.
For durability of nishes and surfaces you should contact the relevant manufacturer for
their specication and avoid materials with temperature ratings less than 80deg C.
B9 Fascia
If using a (velo) fascia, the cutout required in the nished plaster board dimensions are:
410
DX1000: MIN
1100
DX1500: MIN
1600
10
FA S C I A
Note that 10mm (or less) wall lining must be used when installing a DX-series replace with a
fascia, as this is the distance the fascia sits o the front face of the re as shown.
B10 Mantle Clearance
Please refer to the diagram. Mantles or protruding ledges above
the heater must not be installed lower than the dimension shown.
Note: dimension from base of appliance.
B11 Television Clearances
The following are the recommended minimum clearances for the
location of any electrical equipment (such as a Plasma TV, LCD TV
or home theatre system) above an Escea DX Series gas re.
Note: The above television clearance recommendations are to be
treated as a suggestion of a suitable installation only. It is the re-
sponsibility of the end user to check the installation instructions of
their electrical appliances to ensure that the location in relation to
the gas re is suitable. Escea in no way guarantees or takes respon-
sibility that the above installation suggestion will be suitable for all
electrical or home entertainment appliances.
Note: Dimension from base of appliance.
800
MIN
800
MIN
WALL OPENING
(WITH FASCIA)
WALL OPENING
(WITHOUT FASCIA)