Service manual

B
ACDEFGSERVICE
11
B5 Framing Dimensions
DX1000: MIN
800
MIN
450
MIN
381
Front Side
Single Sided
Side
Double Sided
1400
DX1500: MIN
1900
Guidelines for Framing Dimensions - Bench top / Hutch style
1150 MIN
400 MIN
Adequate space to provide
gas inlet connection.
B6 Cavity Base
This appliance MUST be fully supported on its base, over the entire area of the underside
of the appliance. The base must also be level and strong enough to support the total
product weight, which is approximately 100kg (DX1000) or 120kg (DX1500).
B7 Hearth
No hearth is required
B8 Wall Linings
The appliance must be installed prior to and behind the nished wall surface. Take into
account any plaster board, tiles or any other nishing surface that may be intended for
the nished wall surface. Wall nishing materials must not encroach upon the minimum
cavity clearances given in previous sections. The wall board that lines the outside of the
opening can be normal plaster board and does not need to be non-combustible.
Note: The nal wall lining must not encroach within the specied dimensions in this sec-
tion or section B8. These dimensions indicate the opening required in any wall lining.
These dimensions are for DX1500 / DX1000 without fascia, if using a fascia then please
check the following section of this manual for separate wall lining dimensions.
If not using a fascia, ensure the edge of the wall lining is nished in a tidy manner.