Service manual

B
A C D E F G SERVICE
46
S6 Removing or Cleaning Fan
As part of regular service procedure, it is recommended that the fan is removed for clean-
ing. Dust will build up on the fan rotor and in the cavity where the fan is located. This can
be removed by the service person using a hearth brush and a vacuum cleaner.
ISOLATE THE POWER AND GAS SUPPLY TO THE FIRE BEFORE COMMENCING THIS
PROCEEDURE
Step 1: Remove the inner/outer fascia, front glass, and log set as described in section S4.
Step 2: Remove the guard covering the
electrical connections and earth lead by
removing the 3 screws.
Step 2: Disconnect the gas supply from
the re and unplug the three wiring
looms connecting the valve and spark
electrode on the bottom right of the re
box. Unscrew the earth strap
Step 3: Remove the 2 screws holding the
pressure switch bracket. Carefully pull the
switch out and remove the hoses from
the rear of it.
Step 5: Remove outer shell top by removing
the screws in each corner and sliding out.