Service manual
B
A C D E F G SERVICE
46
S6 Removing or Cleaning Fan
As part of regular service procedure, it is recommended that the fan is removed for clean-
ing. Dust will build up on the fan rotor and in the cavity where the fan is located. This can
be removed by the service person using a hearth brush and a vacuum cleaner.
ISOLATE THE POWER AND GAS SUPPLY TO THE FIRE BEFORE COMMENCING THIS
PROCEEDURE
Step 1: Remove the inner/outer fascia, front glass, and log set as described in section S4.
Step 2: Remove the guard covering the
electrical connections and earth lead by
removing the 3 screws.
Step 2: Disconnect the gas supply from
the re and unplug the three wiring
looms connecting the valve and spark
electrode on the bottom right of the re
box. Unscrew the earth strap
Step 3: Remove the 2 screws holding the
pressure switch bracket. Carefully pull the
switch out and remove the hoses from
the rear of it.
Step 5: Remove outer shell top by removing
the screws in each corner and sliding out.