Service manual

B
ACDEFGSERVICE
45
S3 Checking Operating Pressure:
See section E14 of this manual.
S4 Cleaning the Log Set and Glass:
NEVER RUB THE FASCIA. The outside of the fascias must only be cleaned with a clean damp
cloth, dry o after cleaning. The high temp silver powder coating that is used on Escea fascia
parts contains certain amounts of aluminium that when rubbed too hard will oxidise leaving
a black smudge that cannot be removed. Always clean when cold.
This is a service procedure that will need to be carried out whenever soot builds up on
logs and/or inside of glass. If soot build up becomes excessive or regular then one of the
following actions may be required;
Reset gas pressure, pressure may be too high;
Reposition log set so that front edge of each log is just behind each row of holes in
burner top;
Clear any blockage from primary air port of burner;
Check ue tube is not damaged or disconnected.
For diagrams and further info on removing your fascia, reverse the steps found in section F.
Remove fascia bottom panel by pulling it o the magnets that retain it to the re.
Remove the 2 screws holding the inner fascia, lift o the inner fascia by pulling the
base of the inner fascia out and lifting it up and o.
Unscrew the side and top glass retainers and remove them. Take care that the glass
does not fall forwards at this stage.
Lift out glass and place it carefully aside.
Take out fuel bed and gently brush any soot from log with a soft hearth brush. The
burner tops can be vacuumed to remove any excess material.
Clean the inside and outside of glass with normal glass cleaning products. Use a
CLEAN DRY cloth only. Stubborn marks may be cleaned with a ceramic glass cleaner.
Replace in opposite order and test run heater.
S5 Servicing the Horizontal Powerue Wall Terminal
If the Horizontal Powerue Wall Terminal needs servicing, the fan can be accessed from
the outside of the installation.
Ensure the power to the Horizontal Powerue Wall Terminal is o by disconnecting the
power to the appliance inside. If the appliance has been running, allow the terminal to
cool before attempting to service it.
Undo the ten screws holding the outer cowl in place and pull the whole plate and cowl
directly outwards. Note: Be careful of any ash-
ing that may have been installed above the
terminal.
Removing this plate gives complete access to
the fan for servicing or replacement.
Check that all the seals are still intact. Check the
fan electrical terminals, motor and impellor are
not corroded. Ensure there is no signs of leakage
in or around the terminal.
When reassembling the terminal, line up the
round silicon grommets with the outlet tube of the fan and push the cowl back into
place. Ensure all seals are still in place and replace all of the screws to hold the cowl in the
correct position.
Servicing a vertical Powerue:
If the vertical Powerue needs servicing the fan can
be accessed without disturbing the nal twin walled
ue length or roof terminal.
To gain access to the fan and electrical terminals
remove the eight screws that hold the base of the
Powerue to the lid, making sure to support the
base while removing the screws.
Note: When inspecting or working on the Powerue
take care not to damage the two exible ue pipes
that connect to the Powerue base.
Once the base has been removed clean away any dust or debris found and check that the
fan electrical terminals, motor and impellor are not corroded. Also check for signs of leak-
age in or around the Powerue.
When reassembling the Powerue support the base under the lid and replace the 8
securing screws. After assembly check that the two exible ue pipes are sealed and not
damaged and that the twin walled nal ue length and roof terminal are still sealed.
Note : Take care not to trap any wires between the base and lid of the Powerue when
reassembling.