E14 Checking the Operating Pressure
WARNING: The regulator that is supplied with the re MUST NOT BE REMOVED. Removal
of the regulator, or replacing it with one not intended for use with an Escea re, will void
the limited appliance warranty.
Check the operating pressure at the regulator located at the front RH corner of the appli-
ance. This is best done before the fascia panels have been tted to avoid fascia damage. A
pressure test point is available for the operating test pressure (as shown below).
Maxitrol
Beckley
A
B
C
A
D
C
A = Operating Pressure test point
B = Pressure adjustment screw (To access rst remove metal cap)
C = Inlet gas connection ( ½” Female BSPT)
□ Check the inlet pressure to the appliance. Attach manometer tube to the rst test
point upstream of the appliance (typically at the gas utility meter or auto change device
for a propane bottle station)