Service manual

B
A C D E F G SERVICE
12
775 565
Downward
Flue
Vertical or
side Flue
B5 Cavity Base:
This appliance MUST be fully supported on its base. The base must extend over the entire
area of the underside of the appliance. The base must also be levelled to prevent vibra-
tion from possible fan imbalance. The base of the cavity must be strong enough to sup-
port the total product weight, which is approximately 65kg (DL850) and 80kg (DL1100),
depending on fuel bed.
B6 Hearth:
The base of the appliance must be installed a minimum of 100mm o the oor, unless the
appliance is being installed at oor level in which case a hearth is required, made from
non-combustible material and must extend no less than 300mm from the front of the re.
This hearth should be at least as wide as the re’s outer fascia and no less than 10mm
thick. Raised hearths can be any size but must also be constructed from non-combustible
materials.
The oor in front of this hearth will still get warm so if the oor covering is vinyl, nylon
carpet or another heat sensitive material then we recommend extending the hearth to
450mm from the re. A raised hearth can be of any size but must be constructed from
non-combustible materials. NOTE: If the hearth is to be covered with tiles or some other ve-
neer then the re must be installed so that the base of the appliance is level with the nished
top surface of the hearth.
QUADRATO or QUADRATO LITE FASCIA ONLY: The fascia must not be installed ush against a
hearth as the replace draws air from the lower surface of the fascia. As such the fascia must be
raised a minimum of 25mm from a hearth.