B3 Flue Conguration (If more than 4m ue length is required):
If your ue system is greater than 4m long (as shown in diagrams below), then a exible
ue with condensate trap and rigid PP tube ue lengths is required.
4m
Ø80mm / Ø100mm
Flexible Flue
1.2m Co-axial Flue
Vertical Powerflue
12m MAX
Ø100mm
Condensate Trap
Ø80mm / Ø100mm
PP Tube
For further information and
detail on PolyPro (Rigid) ue
and condensate traps, see the
documentation supplied with
the ue components.
4m
ESCEAWALL
TERMINAL
12m M AX
Ø80mm / Ø100mm
PP Tube
Ø100mm
Condensate Trap
Ø80mm / Ø100mm
Flexible Flue
B4 Fascia:
The cavity shape is dependent on the fascia type. There are four fascia types available
with the DL850 and DL1100:
Velo (4 Sided)
Rado
Quadrato
Quadrato Lite
The Velo, Quadrato and Quadrato Lite fascias sit proud of the nished wall surface and
have a simple cavity shape. The cavity may be constructed from combustible materials.
The Rado fascia sits ush with, or inset from, the nished wall surface and has a more
complex cavity shape. The cavity framing and wall facing for a minimum of 300mm
directly above the Rado fascia must be constructed from non-combustible materials.
Please check the style of fascia before commencing the building of the cavity to the
dimensions shown below. The cavity for Velo, Quadrato and Quadrato Lite fascias may be
constructed from combustible timber framing materials. Note: It is not necessary to line
the sides, top or back of the cavity.
Cavity for Rado Fascia
Cavity for Velo, Quadrato or
Quadrato Lite Fascia
Ideal Cavity Dimensions (mm):
DL850: A B (min) B (max) C (min) D E (min) E (max)
Velo / Quadrato
/ Quadrato Lite
965 560 575 565 - - -
Rado 965 585 590 565 995 30 130
DL1100:
Velo / Quadrato
/ Quadrato Lite
1265 560 575 565 - - -
Rado 1265 585 590 565 1295 30 130
NOTE: The nal cavity size and shape should account for the ue direction as shown on