SDS

Safety Data Sheet
29 CFR 1910.1200
Effective Date
01/01-2022
Trade Name
Alkaline Manganese Button Cell (Mercury Free)
-
Cell
5
Fire
-
fighting measures
Suitable extinguishing agents:
CO
2
extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
Special hazards arising from the substance or mixture: No further relevant information available.
Special protective equipment and precautions for firefighters
Protective equipment: Mouth respiratory protective device.
6 Accidental release measures
Personal precautions, protective equipment and emergency procedures:
Wear protective equipment. Keep unprotected persons away.
Environmental precautions:
Do not allow product to reach sewage system or any water course.
Inform respective authorities in case fo seepage into water course or sewage system.
Do not allow to enter sewers/surface or ground water.
Methods and material for containment and cleaning up:
Use neutralizing agent.
Dispose contaminated material as waste according to item 13.
Ensure adequate ventilation.
7
Handling and storage
Precautions for safe handling:
Thorough dedusting.
Ensure good ventilation/exhaustion at the workplace.
For the general occupational hygienic measures refer to Section 8.
Information about protection against explosions and fires: No special measures required.
Conditions for safe storage, including any incompatibilities
Requirements to be met by storerooms and receptacles: No special requirements.
Information about storage in one common storage facility: Not required.
Further information about storage conditions: Keep receptacle tightly sealed.
Specific end use(s):
No further relevant information available.
8 Exposure controls / personal protection
Components with limit values that require monitoring at the workplace:
1313-13-9 manganese dioxide (25.1-29.7%)
PEL (USA) Ceiling limit value: 5mg/m
3
as Mn
REL (USA) Short-term: 3mg/m
3
Long-term: 1mg/m
3
as Mn
TLV (USA) Long-term: 0.02*0.1* mg/m
3
as Mn
* respirable **inhalable fraction
1310-58-3 potassium hydroxide (3.72-4.88%)
REL (USA) Ceiling limit value: 2mg/m
3
TLV(USA) Ceiling limit value: 2mg/m
3
7782-42-5 Graphite (3.42-4.12%)
PEL (USA)
Long-term value: 15mppcf*mg/m
3
*impinge samples counted by light field techn.
REL (USA)
Long-term value:2.5*mg/m
3
*respirable dust
TLV(USA)
Long-term value:2*mg/m
3
all forms except graphite fibers; *resp. fraction
7440-02-0 nickel(1.48-1.57%)
PEL (US)
Long-term value:1mg/m
3
REL (US)
Long-term value: 0.015mg/m
3
(Contd. on page 5)
(Contd. on page 3)