Product: Air Conditioner Remote Control Model Code/s: RG52E1 User Manual Exactly what you need Online: esatto.house RG52E1 - UserManual_V1.
User Manual 2 Welcome Residentia Group — Head Office 165 Barkly Avenue Burnley Victoria Australia 3121 — ACN 600 546 656 — Online residentia.group — Postage PO Box 6077 Collingwood North VIC Australia 3066 — Telephone 1300 11 4357 — Email support@residentia.group Congratulations on purchasing your air conditioner. The Esatto brand is proudly distributed within Australia by Residentia Group Pty Ltd.
esatto.house Contents RG52E1 - UserManual_V1.
User Manual 4 Your Control Handling Remote the remote controller Location of the remote controller. Use the remote controller within a distance of 8 meters from the appliance, pointing it towards the receiver. Reception is confirmed by a beep.
esatto.house Specifications Remote Controller Specifications Model RG52E1/BGEF,RG52E2/BGEF Rated Voltage 3.0V(Dry batteries R03/LR03×2) Signal Receiving Range 8m Environment -5OC~60OC Performance Feature 1. Operating Mode: AUTO, COOL, DRY, HEAT(enabled on cooling& heating models only ) and FAN. 2. Timer Setting Function in 24 hours. 。 。 3. Indoor Setting Temperature Range : 17 C~30 C. 4. Full function of LCD (Liquid Crystal Display).
User Manual 6 Remote Buttons Function buttons 1 ON/OFF Button Operation starts when this button is pressed and stops when this button is pressed again. 2 MODE Button Each time the button is pressed, the operation mode is selected in a sequence of following: AUTO ON/OFF 2 MODE 9 TIMER ON 10 TIMER OFF 11 TEMP 3 FAN 4 SLEEP 5 ECO TURBO SELF CLEAN HEAT FAN 3 FAN Button Used to select the fan speed in four steps: AUTO LOW MED HIGH 4 SLEEP Button Active/Disable sleep function.
esatto.house 8 9 8 1 ON/OFF 2 MODE 3 FAN 4 SLEEP 5 ECO 9 TIMER ON 10 TIMER OFF 11 TEMP TURBO SELF CLEAN 12 LED FOLLOW ME 14 6 7 RG52E1/BGEF UP Button( ) Push this button to increase the indoor temperature setting in 1oC increments to 30oC. DOWN Button( ) Push this button to decrease the indoor temperature setting in 1oC increments to 17oC. ECO Button: Used to enter the energy efficient mode.
User Manual 8 12 C. C. Swing Button(applicable for RG52E1/BGEF) Used to stop or start horizontal louver movement or set the desired up/down air flow direction. The louver changes 6 degree in angle for each press. If keep pushing more than 2 seconds, the louver will swing up and down automatically. 8 1 ON/OFF 2 MODE 3 4 5 ECO 9 TIMER ON 10 TIMER OFF 11 SWING Button(applicable for RG52E2/BGEF) 12 13 Used to stop or start horizontal louver auto swing feature.
esatto.house LCD Display Indicators on LCD Mode display Displays the current operation mode. Including auto( ), cool( ), dry( ), heat( ) (be applicable to cooling & heating models only ), fan( ) and back to auto( ). Transmission Indicator This transmission indicator lights when remote controller transmits signals to the indoor unit. 3 ON/OFF display Displayed by pressing the ON/OFF button. Press the ON/OFF button again to remove. 1 TIMER ON display Displayed when TIMER ON time is set.
User Manual 10 Remote Operation How to use the buttons Auto operation 2 3 ON/OFF 1 MODE ECO TIMER ON NOTE TEMP FAN 1. In the Auto mode, the air conditioner can logically choose the mode of Cooling, Fan, and Heating by sensing the difference between the actual ambient room temperature and the setting temperature on the remote controller. 2. In the Auto mode, you can not switch the fan speed. It has already been automatically controlled. 3.
esatto.house Dehumidifying operation 2 3 ON/OFF 1 MODE ECO TIMER ON TEMP FAN TIMER OFF Ensure the unit is plugged in and power is available. The OPERATION indicator on the display panel of the indoor unit starts flashing. 1. Press the MODE button to select DRY mode. 2. Press the UP/DOWN buttons to set the desired temperature. The temperature can be set within a range of 17 O C~ 30 O C in 1 OC increments. 3. Press the ON/OFF button to start the air conditioner.
User Manual 12 Remote Operation (Continued) Timer operation Press the TIMER ON button can set the auto-on time of the unit. Press the TIMER OFF button can set the auto-off time of the unit. To set the Auto-on time. ON/OFF ECO MODE TIMER ON 1 TIMER OFF 2 TEMP FAN SLEEP TURBO SELF CLEAN LED FOLLOW ME 1. Press the TIMER ON button. The remote controller shows TIMER ON, the last Auto-on setting time and the signal "H" will be shown on the LCD display area.
esatto.house ! CAUTION The effective operation time set by the remote controller for the timer function is limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10, 11, 12, 13, 14, 15,16,17, 18, 19, 20, 21, 22, 23 and 24. O Se Example of timer setting TIMER ON (Auto-on Operation) The TIMER ON feature is useful when you want the unit to turn on automatically before you return home.
User Manual 14 Remote Operation (Continued) TIMER OFF (Auto-off Operation) The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed. The air conditioner will stop automatically at the set time. Stop On Set 10 hours later t rn t Example: To stop the air conditioner in 10 hours. 1. Press the TIMER OFF button, the last setting of stopping operation time and the signal "H" will show on the display area. 2.
esatto.house TIMER ON → TIMER OFF (Off → Start → Stop operation) This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the house. Start Stop Off Set 2 hours later after setting RG52E1 - UserManual_V1.indd 15 5 hours later after setting Example: To start the air conditioner 2 hours after setting, and stop it 5 hours after setting. 1. Press the TIMER ON button. 2. Press the TIMER ON button again to display 2.0H on the TIMER ON display. 3.
This page is intentionally left blank User Manual 16 Appliances Exactly what you need A RESIDENTIA GROUP INITIATIVE RG52E1 - UserManual_V1.