Weekly or as needed depending on use:
• Remove the wire guide and check for wear and dirt deposits. Exchange if needed.
Monthly or more often at heavy use (i.e. more than 8 hours/day):
• Blow out the wire guide channel with compressed air (remove contact tip and wire guide).
• Make sure that all screws are tightened.
• Inspect all connections and hoses for damages.
Damage of the electrical isolation must be repaired by trained personnel before the system
can safely be operated. When in doubt, exchange the whole cable assembly and send it in
for inspection and repair by ESAB.