6. If present insert the control cable plug (10) into the connector (11) and make sure it is
firmly seated.
7. M5×35 screw
8. Washer
10. Control cable plug
11. Control cable connector
12. Micro switch
13. Index pin
7. Gently push back the cable assembly into the robot arm and carefully seat the KSC-2 or
FLC-2 cover (1) in place. Observe the index pin (13) to be in the correct position. Make
sure the two micro switches (12) are not damaged if present.
8. Insert the three M5 screws (14) and tighten without excessive force.
13. Index pin
14. M5×12 screws