User manual
4 TECHNICAL DATA
0463 373 101
- 16 -
© ESAB AB 2015
4.4 Cable assemblies
The connection to the wire feeder is effected by the cable assembly, the available versions
mainly depending on system design and cooling media (gas or water), see the spare parts
list.
The ratings are valid for cable lengths from 1 to 5 m.
Standard cable
assembly
Infiniturn Helix
Rating (10 min. cycle)
• Gas cooled (mixed
gas)
• Water cooled
• Max. 500 A / 60 %
duty cycle
Max. 350 A / 100
% duty cycle
• Max. 600 A / 100
% duty cycle
• Max. 400 A / 60 %
duty cycle
Max. 330 A / 100
% duty cycle
• Max. 550 A / 100
% duty cycle
• Max. 400 A / 60 %
duty cycle
Max. 330 A / 100
% duty cycle
• Max. 550 A / 100
% duty cycle
Rotational range Not rotatable Endlessly rotatable ± 270° from neutral
position
Weight
• Gas cooled
• Water cooled
1.2 m long:
• 2.35 kg
• 2.35 kg
1.0 m long:
• 2.0 kg
• 2.0 kg
1.0 m long:
• 2.0 kg
• 2.0 kg
4.4.1 Cable assemblies for standard RT system
Item Description Function
1 Neck support flange Interface to torch
2 Protective cover Protects the cable assembly from
damage
3 Control cable, 4-pole Electrical connection for safety-off
function (blue/black) and for push-button
(brown/white)
4 Connection for nozzle sense function
(optional)
5 EURO central connector Connection to the wire feeder
6 Blow-out hose (black cap) For cleaning the torch with cmpressed air
after welding
7 Water inlet (blue cap) Water inlet for cooling of the torch