User manual

4 TECHNICAL DATA
0463 373 101
- 14 -
© ESAB AB 2015
Electrical control circuit for
nozzle sense function
Rating:
For Helix cable
assemblies: max. 50 V DC
/ 5 A, max. 1 minute
After detection of contact,
the sensing voltage should
be disconnected quickly.
For Infiniturn cable
assemblies, the nozzle
sense function has limited
functionality. Please
contact us for a detailed
investigation of possible
solutions in your
application.
Rating:
For Helix cable
assemblies: max. 50 V DC
/ 5 A, max. 1 minute
For Infiniturn cable
assemblies: max. 50 V DC
/ 1 A, max. 1 minute
After detection of contact, the
sensing voltage should be
disconnected quickly.
Voltage rating The maximum permitted
voltage for the safety off
control circuit is 48 V.
4.2.2.1 KSC-2 torch mount with safety-off mechanism
Item Description Function
1 Torch neck support Interface to Aristo RT torch
2 KSC-2 cover Assembly with interfaces to cable and torch
3 Rubber boot Protection for safety-off mechanism
4 KSC-2 main body Allows for mechanical deflection during a collision