User manual

4 TECHNICAL DATA
0463 373 101
- 10 -
© ESAB AB 2015
4 TECHNICAL DATA
4.1 Welding torch
The torch model has to be chosen according to the welding application. The required
duty-cycle and capacity, the cooling method, and the wire diameter must be considered. If
there are increased requirements, for example caused by preheated work pieces, high heat
reflection in corners, etc, these must be taken into account by selecting a welding torch with
adequate reserve in power rating.
The RT welding torches are intended for the use with CE-conform welding power sources for
the processes of metal inert gas welding (MIG), metal active gas welding (MAG) and metal
inert gas soldering with commercial round wires. Do not use the torch for other processes.
For aluminium welding the RT82W water cooled torch must be used.
See the spare parts list for available torch models.
Guiding method By machine only
Temperature ranges Storage -15° to 50°C (5° to 122°F)
Operation to 40°C (41° to 104°F)
Blow-out gas Max. 10 bar, separate gas hose
Total weight with torch and 1 m cable
assembly
Approximately 5 kg
4.1.1 Voltage rating
Max. permitted voltage / amperage
Complete welding torch system 141 V (peak value for welding)
KS-2 safety-off control circuit
KS-2 push-button
24 V / 1 A
48 V / 0.1 A
KSC-2 safety off control circuit 48 V
Using nozzle sense functionality with a
standard cable assembly
50 V / 5 A
(Allowed load max. 1 minute at the rated
nominal current)
Using nozzle sense functionality with Helix or
Infiniturn cable assemblies
50 V / 5 A
(Allowed load max. 1 minute at the rated
nominal current)
For detailed information regarding the rating and technical specifications of your torch please
see the spare parts list included with the torch. The values for torch rating and duty cycle are
valid for a 10 min. cycle.
The indicated ratings refer to a standardized case of use. In special cases, e.g. in case of an
especially high heat reflection on the torch, the torch may overheat at lower currents than
indicated. In this case, please use a more powerful model or reduce the duty cycle.
The rating will be notably reduced with the use of pulsed arc power sources.
For cable assembly ratings, see section "Cable assemblies".
4.1.2 Cooling circuit limits
Valid for water cooled version only.