Specifications

73
SECTION 6 REGULAR MAINTENANCE
6.1 Buss Supply Power Control / IGBT Testing Procedure (1)
38
SECTION 5.5 _ TEST IGBT _ 1
Take measurements on threaded part below insulated chrome plated spacer.
With meter on “OHMS (:)” setting, measure resistance
by placing the red (+) lead on the Col
lector (C3 E1) and
the black (-) lead on the Emitter (C1) of the IGBT.
Connect a 9 VDC battery with the negative on the Emitter
(E1) and the positive on the Gate (G1). The meter should
register a low reading.
The Gate should remain on once it has activated.
Short the Emitter / Gate (G1-E1) leads to turn the IGBT off.
IGBT Testing
With meter on “OHMS (Ω)” setting, measure resistance by
placing the red (+) lead on the Collector (C2 E1) and the
black (-) lead on the Emitter (C1) of the IGBT.
Connect a 9 VDC battery with the negative on the Emitter
(E1) and the positive on the Gate (G1). The meter should
register a low reading.
The Gate should remain on once it has activated. Short the Emitter / Gate (G1-E1) leads to turn the IGBT o.
Take measurements on threaded part below insulated chrome plated spacer.
CONTENTS