Specifications

44
SECTION 5 MACHINE TESTING / TROUBLESHOOTING / SERVICE
5.7 Control Transformer T2 - 230/400/460/575V (332914)
TERMINAL VOLTAGE TURNS AWG
H1 - H2 * 230.0 600T 26
H1 - H3 402.5 ± 0.4 1050T 26
H1 - H4 460.0 ± 0.4
1200T 26
H1 - H5 575.0 ± 0.4 1500T 26
X2 - X2 24.8 ± 0.5 65T 25
X3 - X4 20.2 ± 0.4
53T 25
X5 - X6 12.4 ± 0.4 32T 25
X7 - X8 18.4± 0.4 48T 25
X9 - X10 12.4 ± 0.4 32T 25
X11 - X12 125 ± 0.4 326T 25
* H1 - H2 COIL IS EXCITATION WINDING
CONTENTS