Specifications

14
NOTE: PC650 input cable dierences
The colors of input phases of the CE models dier from those of the “non CE” models. Below is a table
comparing the two:
Input Standard
L1 Black
L2 Red
L3 White
GND Green
Input CE
L1 Brown
L2 Grey
L3 Black
GND Green/Yellow
400 & 460-Volt CE
For the 400 and 460-Volt units, it isn’t important which leg is connected to L1, L2 and L3, when 3-Phase
input is used, however if inputting 1 phase power, L2 will be the un-used leg. The T2 must have power to
operate and it is connected across L1 and L3.
208/230-Volt models
**FOR SINGLE-PHASE CONNECTION OF 230-Volt CE MODELS:**
If single-phase connection is desired, connect the BLACK leg to “L3” and the BROWN leg to “L1” with the GREY
(L2) leg disconnected, lugged, and taped back. , L2 will be the un-used leg. The T2 must have power to
operate and it is connected across L1 and L3
SECTION 3 SPECIFICATIONS
3.1 208 / 230 Wiring
CONNECTIONS
PRIMARY ELECTRICAL INPUT CONNECTIONS
FIGURE 3.1
A line (wall) disconnect switch with fuses or circuit breakers should be provided at
the main power panel (see Fig. 3-1 and Table 3-1 for fuse sizes). The input power
cable of the console may be connected directly to the disconnect switch or you
may purchase a proper plug and receptacle from a local electrical supplier. If using
plug/receptacle combination, see Table 3-1 for recommended input conductors for
connecting receptacle to line disconnect switch.
ELECTRIC SHOCK CAN KILL! Precaution-
ary measures should be taken to provide
maximum protection against electrical
shock. Be sure that all power is off by
opening the line (wall) disconnect switch
and by unplugging the power cord to the
unit when connections are made inside of
the power source.
Be sure that the power source is properly
configured for your input power supply. DO
NOT connect a power source configured for
208/230 V to a 460 V input power supply.
Damage to the machine may occur.
CONTENTS