Specifications
11
The Powercut 650 is available as 208/230 VAC single-phase power, or as 460 VAC 3 phase.
The 208/230 volt model comes congured from the factory for 230 VAC operations. If using a 208 VAC
source for operation, the Powercut 650 must be recongured before using a 208 VAC source (See Section
3.1).
Note: The 460 VAC 3 phase unit is designed to work best when 3 phase input power is used, however
with a slight de-rating of the machine output, the PC650 can be used on single phase.
Reasons for de-rating:
Input diode stress. 1 phase uses 4 diodes at higher current levels
Buss capacitors will see higher ripple currents
SECTION 3 SPECIFICATIONS
3.0 Power Specications
PC650 PHYSICAL INFORMATION
Length 16” (406 mm)
Length w/handles 25.70” (653 mm)
Height 16.38” (416 mm)
Width 12.50” (318 mm )
Weight 53 lbs (16 kg)
Shipping Weight 71 Lbs ( 32.3 Kg)
PC650 Power Specications
Output:
40% duty cycle 40A/120V
60% duty cycle 30A/120V
100% duty cycle 22A/120V
Output Current Range 10 to 40 Amperes
Open Circuit Voltage 290 Vdc Nominal
Input @ 40A/120V
208/230 vac 1 ph. 50/60 Hz., 35/32 amps
Input @ 40A/120V 460 vac 3 ph. 50/60 Hz., 8/5 amps
Power factor @ 40A Output
76% (1 Phase)
Eciency @ 40A Output
85% (Typical)
Air requirements 250 cfh at 80 psig
208/230 Volt PN: 0558003179 Console only
460 Volt PN: 0558005328 Console only
CONTENTS