Specifications

VCES-ERV-IOM-3B – Indoor ERV
3
Nomenclature
1. FROST CONTROL
D – Recirc defrost
1
E – Exhaust only
2
V – VSD frost prevention, no
wall control compatibility
W VSD frost prevention
C Non-defrost
N – Non-defrost, no wall
control compatibility
3
13. ENERGY RECOVERY
1 – Aluminum wheel, no purge
2 – Aluminum wheel c/w purge
12. CASSETTE ACCESS
R Reverse cassette access
S – Standard cassette access
11. LOW SPEED
L – Reduced low speed
N – Normal low speed
X – No low speed
10. FREE COOLING
S – Setpoint for enthalpy controller
D – Differential enthalpy controller
T – Thermostat (dry bulb)
X – No free cooling controller
9. FILTRATION
S – Supply filter
E – Exhaust filter
B – Supply and exhaust filters
X – No filtration
8. EXTERNAL DISCONNECT
F – Fused disconnect switch
9
N – Non-fused disconnect switch
9
X – No disconnect switch
2. VOLTAGE/SPEED
A – 120/1/60 - two-speed
4
B – 208–120/1/60 - two-speed
4/5
C – 230–120/1/60 - two-speed
4/5
D – 208/3/60 - one-speed
4
E – 230/3/60 - one-speed
4
F – 460/3/60 - one-speed
4
3. INTERNAL PROTECTION
1 – 1” insulation, single wall
2 – 1” insulation, double wall
4. SENSOR CONTACTS
D – Dirty filter contacts
W Wheel rotation sensor
6
B – Dirty filter contacts and wheel rotation sensor
6
X – No contacts, no sensor
5. EXTERNAL FINISH
S – Standard galvanized package
W White prepaint package
6. OUTSIDE AIR DAMPER
1 – Insulated motorized
7
2 – Insulated spring return
7
3 – Non-insulated motorized
8
4 – Non-insulated spring return
8
5 – No damper
7. DOOR FASTENERS
S – Standard filter door c/w screws
D – Deluxe filter door c/w ¼ turn fasteners
Notes:
1 When ordering recirc defrost, you must order an insulated outside air damper. Recirc defrost option includes recirculation dry contacts for unoccupied mode.
Includes exhaust backdraft.
2 Outside air damper required.
3 No damper required.
4 Single-phase motors are available with low speed options ‘L’ or ‘N’. Three-phase motors are only available with low speed option ‘X’.
5 Requires a neutral wire with L1 and L2.
6 Units ordered with the wheel rotation sensor option must include a frost control option other than ‘V’ or ‘N’.
7 This option is for recirc defrost units only.
8 This option cannot be ordered on recirc defrost units.
9 Fused/non-fused disconnect switch is field installed.
1 2 3 4 5 6 7 8 9 10 11 12 13
ERV1000i Nomenclature (700–1,400 cfm)