Datasheet
SAFETY DATA SHEET
according to Regulation (EC) No. 1907/2006
FLUX NC 5070, 5 G, 5 CC
Version
7.0
Revision Date:
27.02.2020
Date of last issue: 26.02.2020
Date of first issue: 26.11.2015
7 / 19
Intermittent use/release 0,18 mg/l
Sewage treatment plant 10 mg/l
Fresh water sediment 0,547 mg/kg
Marine sediment 0,0547 mg/kg
Soil 0,0986 mg/kg dry
weight (d.w.)
8.2 Exposure controls
Engineering measures
Provide sufficient air exchange and/or exhaust in work rooms.
Personal protective equipment
Eye protection :
Safety glasses with side-shields
Hand protection
Remarks
: Before removing gloves clean them with soap and water.
Gloves should be discarded and replaced if there is any indi-
cation of degradation or chemical breakthrough. Please ob-
serve the instructions regarding permeability and break-
through time which are provided by the supplier of the gloves.
Also take into consideration the specific local conditions un-
der which the product is used, such as the danger of cuts,
abrasion, and the contact time. As the product is a mixture of
several substances, the durability of the glove materials can-
not be calculated in advance and has to be tested before
use.
Skin and body protection :
Choose body protection according to the amount and con-
centration of the dangerous substance at the work place.
Respiratory protection :
Use respiratory protection unless adequate local exhaust
ventilation is provided or exposure assessment demonstrates
that exposures are within recommended exposure guidelines.
Filter type :
Recommended Filter type:
Filter type ABEK-P
SECTION 9: Physical and chemical properties
9.1 Information on basic physical and chemical properties
Appearance
: paste
Colour
:
colourless
Odour
:
solvent-like
Odour Threshold
:
No data available
pH
: 4,8 (25 °C)
Melting point/range
: No data available
Boiling point/boiling range
: 244 °C
(1.013 hPa)
Flash point
: 113 °C(1.013 hPa)
Evaporation rate
:
No data available