User manual

KBD ## IN CONTROL
An operator has tried to PTZ- or Adpro-operate a camera which currently is operated from
another keyboard - keyboard number ##.
Try to override the other keyboard by pressing the MON-button again.
KBD ## USES MONITOR
An operator has tried to select a monitor which currently is selected by a keyboard with a
higher priority - the monitor is therefore not accessible.
KEY REQUIRE LEVEL #
The operator has pressed an Adpro key which is protected by a higher keyboard access level,
than the level currently available to the operator.
MON ## IN ALARM MODE
The operator has tried to select a camera or a sequence to a monitor on which an alarmed
picture is displayed.
MONITOR NOT VALID
The monitor is not accessible to the current keyboard.
MON XX IN SETUP MODE
The operator has tried to select a camera or a sequence to a monitor on which another
operator has entered the setup system.
MONITOR ID NOT FOUND
An operator has tried to select a monitor with an ID-number, which doesn't exist.
NO CONTROL POSSIBLE
The operator has tried to override another operator in order to obtain control on the same
camera. This is not possible due to the other operator keyboard having a higher priority.
NO STATE FOR ALARM
An alarm has been activated, but the alarm is connected to an alarm group which has no alarm
states attached. Basically this means, that no actions is defined for this specific alarm - in fact
all alarms connected to this alarm group.
OVERRIDE MONITOR ##
Press CAM to take a videoline from a lower priority keyboard, that are viewing a camera from a
Remote System.
OVERRIDING KBD ##
The operator has overridden another operator in order to obtain PTZ- or Adpro-control on the
same camera.
PRESS ADPRO FOR CTRL!
The operator has pressed a key related to the Adpro equipment without pressing the
Adpro-key first.
PRESS MON FOR CTRL!
The operator has pressed an pan/tilt, lens or AUX key without pressing the MON-key first.
SEQ ID NOT FOUND
An operator has tried to start a sequence with an ID-number, which doesn't exist.
SIO ## DEVICE NOT IEC
The serial port set up in the Camera menu, does not match the setup of the actual serial port.
SIO ### MUST BE ADPRO
The Adpro equipment is connected to the serial port number ###, but this serial port has not
been set to this equipment type.
SIO ### MUST BE PTZ
The operator has tried to PTZ-operate a camera, but the serial port to which the equipment is
connected has not been allocated for PTZ-control via the ERNA protocol.
SYSTEM IS BUSY - TRANSFERRING SETTINGS
The SYSTEM 500M is currently transferring new settings to/from the SYSTEM 500M Set-up
program - while the settings are downloaded/uploaded the alarm handling and other parts of
the system are disabled.
User Manual for SYSTEM 500M
GB - Page 22 Number 2822-00025