Product Overview

2 © Copyright 2013 Schneider Electric All Rights Reserved. F-26496-8
SPECIFICATIONS
Valve Body Assembly
Service Hot and chilled water models, up to 50% glycol. Steam models up to 15 psi (both
valve body and valve actuator must be rated for high temperature).
System Static Pressure Limits 400 psi (2758 kPa).
Close-off Refer to Table-2.
Fluid/Ambient Temperature Limits Refer to Table-1.
Seat Leakage ANSI class IV (0.01%) with pressure at inlet (B-port/A-port, if 3-way).
Body Forged brass.
Stem Nickel-plated.
Seat Brass.
Paddle (VT series) Buna N.
Paddle (VS series) Highly saturated nitrile.
Actuator
Voltage 24 Vac @ 50/60 Hz. 110 Vac @ 50 Hz. and 120 Vac @ 60 Hz., 230 Vac @ 50 Hz.
and 240 Vac @ 60 Hz., 208 Vac @ 50/60 Hz., 277 Vac @ 50/60 Hz.
Power Requirements 6.5 watts, 7.5 Va.
End Switch 24 - 240 Vac Models: 24 - 240 Vac/101 mA min. to 5A max, and 9 - 30 Vdc @
100 mA max.
277 Vac Models: 277 Vac/101 mA min. to 5A max.
Control Signal On/off, 2 position, spring return.
Timing, Full Open to Full Close 25 Sec max for 60 Hz; 30 Sec max for 50 Hz; and 9 Sec
max spring return.
Materials Stainless steel base plate, aluminum cover.
Ambient Temperature Limits:
Shipping & Storage, -40 to 160 °F (-40 to 71°C).
Operating, Refer to Table-1.
Humidity 5 to 95% relative humidity, non-condensing.
Agency Listings UL873: Underwriters laboratories (File #E9429 Catagory Temperature
Indicating and Regulating Equipment). CUL: UL Listed for use in Canada by Underwriters
Laboratory. Canadian Standards C22.2 No. 24. European Community: EMC Directive
(89/336/EEC). Low Voltage Directive (72/23/EEC). Australia: This product meets
requirements to bear the C-Tick Mark according to the terms specified by the
Communications Authority under the Radio Communications Act of 1992.
Shipping Weight (Actuator/Valve Assembly) 2.25 lbs (1020 g).
a: For steam applications both valve body and valve actuator must be rated for high temperature.
Example: VS2213G14A020 = Assembly. VS
2213 = Valve body. AG14A020 = Actuator.
Accessories for Inverted Flare Connection Valves
3/4" inverted flare bodies accept the following adapters to copper pipe:
436-214-1 Union nut & elbow assembly, female for 1/2" (5/8" O.D.) copper, 15/16" long
436-220 Union nut & coupling assembly, female for 1/2" (5/8" O.D.) copper, 1-1/16" long
436-252 Union nut & coupling assembly, female for 3/4" (7/8" O.D.) copper, 1-27/32"
long
436-229-3 Union nut & nipple assembly, male for 1/2" (5/8" O.D.) copper, 3" long
436-214-4 Union nut & elbow assembly, male for 1/2" (5/8" O.D.) copper, 1-15/16" long
436-256 Union nut & coupling assembly, female for 1" (1-1/8" O.D.) copper, 1-3/8" long
Table-1 Valve Body and Actuators Model Chart
Model Temperature Range
VTXXXX 32° to 200 °F (fluid) @ 104 °F (Ambient) (0 to 93 °C @ 40 °C)
VSXXXX 32° to 250 °F (fluid) @ 169 °F (Ambient) (0 to 121 °C @ 76 °C), and/or 15 PSI (103 kPa) Steam
a
AXX3XXX 32° to 200 °F (fluid) @ 104 °F (Ambient) (0 to 93 °C @ 40 °C)
AXX4XXX 32° to 250 °F (fluid) @ 169 °F (Ambient) (0 to 121 °C @ 76 °C), and/or 15 PSI (103 kPa) Steam
a