Operating instructions

Home > SPR1100 Handbook > Looking After The Unit > Troubleshooting > Basic Fault Scenarios > Fans Not
Working/Overheating
Fan(s) Not Working/Overheating
The fans can be disabled at low temperatures to allow the unit to quickly attain operational
temperature. In the event of overheating problems, refer to the following table.
Step
Action
If Result of Action
is Yes…
If Result of Action
is No…
1
Check Fan Rotation.
Inspect the fans
located at the sides of
the enclosure. Are the
fans rotating? Check
Base Board
temperature and fan
(see nCompass
information).
Check that the unit
has been installed
with sufficient space
allowed for air flow
(see Installing the
Equipment >
Mounting in a Rack >
Care in Positioning). If
the ambient air is too
hot, additional cooling
may be required.
Possible break in the
dc supply from the
PSU module to the
suspect fan(s). Call
a Service Engineer.
NOTE:
© Ericsson AB 2011. All rights reserved