Specifications
Appendix
RX8200 Configuration Guide
xi
Figure 46 RX8200 Alarm Menu
Compatibility Vs Dynamic Mode Alarms
The current dynamic mode alarm functionality utilizes the next available incrementing identifier assigned at start-up.
These identifiers will change depending on the cards present in the unit configuration. The compatibility mode setting
allows pre-defined fixed identifiers to be assigned at startup. This in-turn allows the identifier of different units to be
tracked through the external control system consistently
Input
No TS Lock – Select the alarm condition from the drop-down menu to be activated when Transport Stream loses
lock (Set Alarm /No Alarm).
No TS Lock (relay mapping) – Place a check mark in the box to activate relay mapping for Transport Stream loss of
lock alarm.
No Primary Input Lock – Select the alarm condition from the drop-down menu to be activated when Primary Input
loses lock (Set Alarm /No Alarm).
No Primary Input Lock (relay mapping) – Place a check mark in the box to activate relay mapping for Primary
Input loss of lock alarm.
Monitor Inactive Input – Click to place a check mark in the box to activate an alarm when there is no signal present
at the Primary Input .
No Secondary Input Lock – Select the alarm condition from the drop-down menu to be activated when Secondary
Input loses lock (Set Alarm /No Alarm).
No Secondary Input Lock (relay mapping) – Place a check mark in the box to activate relay mapping for
Secondary Input loss of lock alarm.
C/N Margin – Select the alarm condition from the drop-down menu to be activated when the Carrier-to-Noise margin,
set below, is exceeded (Set Alarm /No Alarm).
C/N Margin (min value) – Enter the Carrier-to-Noise margin minimum value in decibels. This is used to trigger the
alarm condition, set above, when exceeded.
C/N Margin (relay mapping) – Place a check mark in the box to activate relay mapping for C/N Margin exceeded
alarm.
Output
IPO Ethernet If 1/2 Down – Select the alarm condition from the drop-down menu to be activated when there is no
signal at IPO Ethernet 1/2 (Set Alarm /No Alarm).
IPO Ethernet If 1/2 Down (relay mapping) – Place a check mark in the box to activate relay mapping for no signal
at IPO Ethernet 1/2.
Service
Video Not Running – Select the alarm condition from the drop-down menu to be activated when video is not running
(Set Alarm /No Alarm).