Specifications

INSTALLATION DIAGRAM
CNI GETC SHELF
MASTR II, IIe INSTALLATION
STCP3Z
(19D417483, Sh. 12, Rev. 27)
When installing GETC Panel 19D901868,
Mount GETC Panel above Radio housing.
If not CNI Application, connect 19C336861P2 sensor to transmit
antenna connector. Remove wire from P19-5 on 19C320811 and
install in P19-5 on 19C336863. Use Hardware Kit
19A130031G30. For CNI Application, refer to Mod. Instruction
344A3498P1, replace PROM Kit 19A149256 with PROM Kit
344A3497 provided, after tune and test. On MIIe Stations, cut the
solid white jumper wires on harness 19C320811G16 from P27-14
to P27-15 and P27-6 to P27-16.
Ericsson Inc.
Private Radio Systems
Mountain View Road
Lynchburg, Virginia 24502
1-800-528-7711 (Outside USA, 804-528-7711) Printed in U.S.A.
LBI-38986