3. Following the instructions in TQ-3357, select the
"GE" directory and execute the "GTC" command.
After a brief introductory screen, the Current
Personalities Screen appears.
The programming software offers menu selections and
function keys for comprehensive GETC Personality
management including:
Creating a new Personality
Reading a GETCs current Personality
Retrieving a Personality from disk storage
Saving a Personality to the disk
Editing an existing Personality
Transferring a Personality to the GETCs memory
4. Read the existing personality from the CNI GETC
to the PC. If the personality does not exist, retrieve
the sample CNI Personality (shown in Figure 13)
from the PC. Change the personality parameters as
required.
5. After entering the personality parameters, select
the "Program Card" function to program the
personality into the GETC.
6. Verify that the GETC has properly stored the
personality data by selecting the "Read Unit Into
File" function while in the Current Personalities
Screen.
7. After completing the programming, save the
revised personality to disk.
8. Reset the DIP switches and press S4 to reset the
GETC.
9. Disconnect the TQ-3360 cable and verify GETC
operation.
Figure 10 - Personality Programming
The Conventional Network Logical ID must be the
same as the Logical ID in the System Manager
Database. This ID must be valid on the corresponding
trunked system(s). Likewise, the Conventional
Network Group ID’s must be the same as the Group
ID’s in the System Manager Database. These ID’s
must be valid on the corresponding trunked systems.
NOTE
LBI-38986