Specifications
2. Remove the contacts (4) from the header (P26) on
the harness 19C337792P1.
3. Remove contacts from 19B802401P1, P6-8 and
P6-9. This is the GETC Transmit Data pair, see
Figure 6.
4. Remove contacts from 19B802401P1, P6-6 and
P6-7. This is the GETC Receive Data pair.
5. Connect the harness assembly (19B802401P1)
plug P6 to the GETC Logic Board connector J6.
6. Connect the harness assembly (19B802401P1)
plug P7 to the GETC Logic Board connector J7.
7. Connect the harness assembly (19B802401P1)
plug P10 to the GETC Logic Board connector J10.
8. Connect the harness assembly (19C336863) plug
P8 to the GETC Logic Board connector J8.
9. Connect the harness assembly (part of
19B802401P1 and 19C336863) plug P19 to the
GETC Logic Board connector J19.
10. Connect the Regulator Board harness assembly
(A2W1) plug P1 to the GETC Logic Board
connector J27.
Jumper Installation
There are a few jumpers on the GETC Logic Board
which must be re-configured for CNI operation. To
properly configure the jumpers, refer to Table 2 and install
or remove jumpers according to table. The location of the
jumpers may be found using the board layout diagram in
Figure 7 or by referring to the full scale GETC Diagrams in
LBI-38988.
GETC FIRMWARE INSTALLATION
The firmware installation procedure involves installing
the latest version of the CNI EPROM (344A3497) into the
CNI GETC.
EPROM Installation
Perform the following steps to install the CNI GETC
firmware:
1. Remove power from the GETC and place the
GETC shelf in the service position. This will
allow access to the EPROM.
2. Remove the GETC EPROM U2.
3. Install the CNI EPROM into the XU2 socket
(ensure the EPROM’s pin 1 is properly aligned
with pin 1 on the socket, see Figure 4).
4. Proceed to the Software Installation procedure.
TURBO SOFTWARE INSTALLATION
The two Turbo Board processors communicate with
each other through a parallel bus. Communication with the
main GETC processor is through the 8K dual port RAM
bank comprised of U3 and U4. In addition, each turbo
processor has an RS-232 serial port used for Turbo
Programming.
CNI stations built in the factory come with the latest
software. To upgrade an existing station, refer to the
software release notes for the appropriate version of the
Turbo Board software. It will vary with the version of
GETC Logic Board software. Group 1 of the CNI software,
344A3497G1, is compatible with Group 1 of the Turbo
Board software, 344A4414G1.
Figure 6 - Simplified Diagram of Modified Harness
This software is subject to change resulting from
improvements or enhancements. When upgrading the
software, the procedures provided in the
accompanying software release notes takes precedence
over this manual.
NOTE
Observe precautions
for handling
ELECTROSTATIC
SENSITIVE DEVICES
CAUTION
LBI-38986
11