Specifications

19A705178
REV NO. TITLE
CONT ON SHEET
8
SH NO.
7
ROCKWELL MODEM TEST
SPECIFICATION/PURCHASE PART DRAWING
CONT ON SHEET SH NO. FIRST MADE FOR
F. C. F. O.
MADE BY
K P Dotson 11-19-86
APPROVALS
DCB
M. R. P. D.
DIV OR DEPT.
19A705178
ISSUED
Nov. 19, 1986
11-18-86
LYNCHBURG
LOCATION
CONT ON SHEET
8
SH NO.
7
REVISIONS
L30
PRINTS TO
5.0 TEST PROCEDURES
5.1 PREPARATION FOR TEST
Refer to the GETC test specification for certain alignment procedures prior to testing of the Rockwell
Modem. Set up terminal with 19.2 KBaud rate, odd parity, full duplex, and all upper case letters. Connect
the terminal to the master communication link as follows:
SIGNAL GETC LOGIC TERMINAL
BOARD (D-TYPE CONNECTOR)
TXD J8-1 PIN 3
RXD J8-2 PIN 2
GND J8-3 PIN 7
SIMON is used to test the Rockwell Modem.