LBI-39000B INSTALLATION
60
7.1.5.2. Configuration of Jessica Site
Perform the steps below to configure Jessica as a site in the System Manager. Refer to LBI-38984, “EDACS VAX/VMS
System Manager User’s Manual,” and Table 7 for more information.
1. Select System Manager menu item 10 Site Definition.
a. Set RF and Allowed CC
according to Table 7.
b. Set Message Conv Limit (suggested setting is 5 minutes).
c. Set Interconnect Hang Time (suggested setting is 30 seconds).
d. Set Rotate Assignments and Assign Chan Ascending as desired.
2. Select System Manager menu item 11 Logical Unit Definition.
a. For each LID on the interconnect system, set the parameters according to Table 8.
3. Select System Manager menu item 12 Group Definition.
a. For each GID on the interconnect system, set the parameters according to Table 9.
4. Select System Manager menu item 14 Line Definition. (This step is required only for multinode Jessica systems.
Please refer to section 4.1.)
a. Set Line Active and Dedicated To Unit
columns according to Table 7.
These settings will not take effect until Jessica is rebooted or the database is uploaded according to LBI-38984, “EDACS
VAX/VMS System Manager User’s Manual.”
7.1.5.3. System Manager Screens Defined for Jessica
Refer to LBI-38984, “EDACS VAX/VMS System Manager User’s Manual,” for information on logging into the System
Manager and general screen format.
The RF field in the System Manager Channel Config screen is not used because it can operate on only 24 of the 32 bit
positions. The Toll Call Restrictions screens are not used also because they support 4-digit restrictions only.