Specifications

Wide Area Scan (Optional)
When the radio unit loses the control channel of the
current system, the radio automatically begins searching for
a new control channel. The intelligent search algorithm uses
a preprogrammed map of adjacent systems to ensure mini-
mum transition time.
Dynamic Regrouping (Optional)
The unit is capable of being reprogrammed over the air
while the radio is still active. Multiple talk groups can be
added to a radio unit or optionally, the radio can be forced to
communicate on designated talk groups.
GE-MARC (Only) FEATURES
Talk Around (Direct Mode)
The radio is capable of a direct unit-to-unit short range
communication link. It is intended to maintain communica-
tions outside the coverage area.
OPERATION
The following section provides a description of the
Controls and Indicators for the Dual Format PCS radio.
Detailed operating instructions can be found in the Opera-
tors Manual LBI-38823.
CONTROLS
ON/OFF
SWITCH
The ON/OFF SWITCH is located on
the battery pack. Sliding this switch
up to the ON position will supply
power to the radio from the battery
pack. The radio will beep once after
power is applied indicating it is ready
for use.
PTT BUTTON
(Push-To-Talk)
Pressing the PTT Button on the side
of the radio will key the radio’s trans-
mitter and perform the necessary steps
to acquire a communication channel.
SHIFT/CLR All alternate key functions are ac-
cessed by pressing the SHIFT/CLR
button and then pressing the desired
function key.
Trunked - Pressing the SHIFT/CLR
button twice ("double click") will in-
voke the CLEAR function which is
used to exit the Special Call mode and
return to the normal system/group dis-
play.
Conventional - Pressing SHIFT/CLR
button twice ("double click") will en-
able MONITORING the channel for
activity by unsquelching the receiver.
All transmissions will be heard, even
if Channel Guard protected.
S The Select buttons are two momen-
tary (auto ramping) switches used to
increment or decrement the current
Group/Channel selection. Pressing
the shift button and then the S buttons
will increment or decrement the Sys-
tem selection. The Select buttons are
also used to increment or decrement
the Special Call selection while in the
Special Call mode.
V The Volume buttons are two momen-
tary (auto ramping switches) used to
increment or decrement the volume
level from the speaker. A tone sounds
each time the Volume buttons are
pressed, except when a call is in proc-
ess.
HOME/E The HOME/Emergency key is used
to automatically select a desired
Group and/or System by pressing and
holding the key for a programmed du-
ration. The HOME/Emergency key
is also used to declare emergencies by
pressing and holding the key for a
preprogrammed duration. Emergency
messages may only be issued on
EDACS systems.
SPC Pressing the SPC call key will put the
radio in the Special Call Mode. From
the Special Call Mode the radio is able
to make individual and interconnect
calls. This key is active with trunked
systems only.
SCAN-A/D The SCAN-Add/Delete key is used to
enable the Scan mode and to add or
delete Groups/Channel to the Scan
list.
STO The STOre key in combination with
the SHIFT/CLR button is used to
store Individual Call numbers and In-
terconnect numbers. This is available
on System Model radios and is active
with trunked systems only.
LBI-38836B