Specifications
MAINTENANCE
RECEIVER
For optimum performance, the unit should be realigned
before being put into service.
Preliminary
1. Program unit for the desired frequency(ies) and
tones. Disable tone on a frequency at or near the
middle of the range of frequency(ies) programmed.
Set the front panel SQUELCH control to the maxi-
mum counter-clockwise position. Set the front
panel VOLUME control to the mid-range position.
Connect an audio RMS voltmeter, SINAD meter,
and distortion meter, if available, to the speaker ter-
minals.
2. For base station units, set the unit to a receive fre-
quency nearest the middle of the frequency list.
The maximum frequency spread is ± 5 MHz;
± 3 MHz for best sensitivity.
NOTE
Figure 5 - Microphone Matching Network
Figure 4 - Equipment Set-Up
AE/LZB 119 1882 R1B
20