Specifications

SERIES 3/3A PROGRAMMING GUIDE
A - 14
Operational modes:
V.21 300bps full duplex
V.22 1200bps full duplex
V.22bis 2400bps full duplex
V.23 1200/75 full duplex 75/1200 full duplex
V.27ter 4800bps fax send and receive
V.29 9600bps fax send and receive
Line connection:
2 wire PSTN via BT 600 type modular jack on flying lead
Signal level:
-9 dBm
Equalisation:
Transmit fixed compromise
Receive automatic adaptive
Interface:
600 ohm
Error correction:
V.42 incorporating LAPM and MNP Class 4
MNP Class 10
Data compression:
V.42bis and MNP Class 5
Autodial/autoanswer
Dial method:
Tone or pulse, selectable
Call progress:
Loudspeaker with on/off control
Extended results codes
Call control:
Extended "AT" command set
Automatic answer:
To CCITT V.25 recommendation
Mode selection:
Automatic configuration to V.21/V.22/V.23/V.22bis and V32/V32bis on
receive
Call disconnection:
Loss of carrier, DTR or by command
BABT Approval
Approval number:
606866
Psion 3Fax Modem Technical Specification
The 3Fax modem has been superseded by the Series 3a PC Card Adapter with a suitable PC Card modem,
combined with the PsiFax software on SSD, (for the Series 3c there is the Travel Modem).
Physical
Part number:
1601-0022-01
Series 3/3s compatibility:
No
Series 3a compatibility:
Yes (512KB, 1MB and 2MB models only)
Work
about
compatibility:
No
Series 3c compatibility:
No
Siena compatibility:
No
EMC:
FCC Part 15 Class B; CE Mark
Environment:
Operating temperature: 0-50C
Operating humidity: 0-95% non-condensing
Dimensions:
165mm x 40mm x 25mm
Power:
2 x AA batteries
or
optional rechargeable NiCad battery pack
or
optional 10V (250mA) DC Series 3a mains adaptor.