Specifications

Masterclock, Inc.
phone (USA and Canada): 1-800-940-2248 | phone (international): +1-636-724-3666
email: sales@masterclock.com | online: www.masterclock.com
Key Features
User programmable pulse width
.0001 to 214,747 seconds
(approximately 2.4 days), with
100 μs resolution
Edge triggered at top of second
and synchronized to PPS
One-shot, pulse train, or
frequency generator modes with
number of cycles up to 4 million
Active high or active low pulse
May be added to MCR1000 and
MCR5000
Masterclock’s MCR-PPO (Programmable Pulse Output) is an
add-in module option for Master Clock Reference devices
which provides a precision time referenced pulse output
synchronized to the PPS of your MCR System.
The PPO option provides a pulse reference based on the high
precision PPS of your Master Clock Reference.
Pulse widths from 100 μs to over 2 days, with resolution of 50
μs, are achievable. You may set your pulse to be active high or
active low, triggered from the top of second. Pulses may be
one shot, or you may use to produce pulse trains or as a
frequency generator.
Each MCR may be ordered with an MCR-PPO module option.
Multi-functional Master Clocks
MCR-PPO Module
1.3. 6
Specifications
Programmable Pulse Output Option
Modes
Frequency generator, one-shot pulse generator,
pulse train (programmable cycles)
Frequency Range 4.657 e-6 Hz to 200 kHz
Pulse Width Range .0001 seconds to 214,747 seconds
Resolution 100 μs
Programmable cycles
1 to 4,000,000 (0 cycles = continuous free
running)
Accuracy ± 50 μs of PPS edge
Pulse Type Active High or Active Low (5V at 20mA)
Trigger MCR System PPS
MCR-PPO Module