User`s manual
LBI-39117
7
4. Connect the two (2) ac power cords, one from
each ac outlet strip, to an appropriate ac power
source.
5. Simultaneously switch both power switches on the
back of the RPS unit to the "ON" position.
6. Verify both "STATUS" indicators on the RPS
unit's front panel are illuminated green. A red or
amber illumination from one indicator indicates ac
power is not applied to the module. Both "TEMP"
indicators should be illuminated green.
7. The cabinet's fan should now be tested. With a heat
gun, trip the fan’s thermostat and verify the fan
switches from low-speed to high-speed operation.
Thermostat trip point is approximately 110º F (43º
C). The fan should return to low-speed operation
when the thermostat cools to approximately 95º F
(35º C).
8. Connect and power-up the CEC Manager (MOM
PC) computer and start its application program,
O_MOMPC.EXE
. Next, log-on to it using the
default user name, "
MOMUSER
" and the default
password, "
GUEST
".
9. Proceed to the CEC Manager's "
SYSTEM
DISPLAY"
screen. This screen is accessed by
selecting the "
View System/Diagnostics
"
option from the CEC Manager's main menu. See
LBI-39024, LBI-39124, etc. for complete details.
10. Now verify all installed Controller Boards in the
upper Card Cage are active by observing the one-
letter symbol reference in the 16 x 16 node matrix
box. One or more of the symbol references may be
flashing to indicate errors. For example if the MIM
is not connected to the EDACS site via the uplink
and downlink GETCs, an "
M
" will be flashing in the
matrix.
If an interface module's Controller Board does not
have a symbol reference displayed, reset the
respective Controller Board by pressing the reset
button on its front panel. At this point, if the
"RUN" LED on the Controller Board is not lit
solid, momentarily remove the board from the
Backplane and verify all DIP switch settings per
the DIP Switch Settings diagram in this manual.
Now, reinsert the board into the same slot. If
necessary, follow the Controller Board live
insertion procedure presented in LBI-38938.
11. Verify the number of "
Total Nodes:
"
displayed on the "
SYSTEM DISPLAY
" screen
matches the number of Controller Boards installed
in the upper Card Cage. This number should be "
5
"
if the C3 Advantage dispatch system has only one
console, "
6
" for a two-console system and "
7
" for a
three-console system. Controller Boards with an
inactive or secondary status and the CCI Controller
Board in the CIA rack do not add to the "
Total
Node
" count.
12. The MOM Controller Board's symbol reference
should be "
O
" in its reserved position (FB hex) on
the "
SYSTEM DISPLAY
" screen.
The MOM Controller Board and the MIM
Controller Board within the primary or upper Card
Cage (Card Cage 1) are referred to as "end nodes"
since they are the far-most Controller Boards on the
ends of the primary Backplane structure. These two
(2) Controller Boards have a special DIP switch
setting to identify them as "end nodes". If all
interface modules' symbol references are flashing,
observe SW1 position 2 on the "end" Controller
Board – the MIM Controller Board in Card Cage
1 slot 2. It should be set to the "1" or "OPEN"
position as shown in the DIP Switch Settings
diagram in this manual.
NOTE
If the MIM Controller Board is removed, the
Controller Board closest to it (CIM 1) should be set
as a temporary end node by setting its SW1
position 2 to the "1" or "OPEN" position. When the
MIM is reinstalled, the temporary end node should
be turned off by setting SW1 position 2 back to the
"0" or "CLOSED" position. A Controller Board
must be reset after a DIP switch change.
13. Check the panel-mounted toggle switches on the
Clock Board. This board is located in Card Cage 1
slot 21. The "A" clock should be off and the "B"
clock should be on.
NOTE
If the redundant clock feature can be used, it may
be enabled at a later time. See the section entitled
"REDUNDANT CLOCK CONFIGURATION"
for details. DO NOT enable the redundant clock
feature at this time.
14. On each Audio Board, verify the "RUN" LED is
flashing, the "RST" LED is off and all other LEDs
are on and not flashing.
15. Now verify each installed Audio Board is active by
viewing its status on the "
HDLC STATISTICS
",
"
CHANNEL B
" screen at the CEC Manager. This
NOTE